2026, 09, v.43 17-22
一体化堆顶结构研发及试验验证
基金项目(Foundation):
邮箱(Email):
DOI: 10.16791/j.cnki.sjg.2026.09.003
发布时间: 2026-09-09
出版时间: 2026-09-09
网络发布时间: 2026-09-09
移动端阅读
摘要:

文章基于耐高温控制棒驱动结构,研究了一体化堆顶结构方案,取消堆顶强制通风,实现堆顶结构模块化安装和吊装,简化换料大修操作。采用CFD数值模拟方法,基于含内热源的导热与对流耦合原理,分析堆顶结构在自然对流、堆腔池辅助通风等不同通风形式下的空气、流体和金属三相散热性能,研究不同工况下反应堆堆顶流场及驱动机构线圈的散热效果;并开展1∶1一体化堆顶试验台架高温通风试验验证。研究结果表明:采用堆腔池辅助通风方式的通风散热性能明显优于自然对流冷却方式,线圈温度明显降低,堆顶区域温度满足各物项耐受温度范围。采用辅助通风一体化堆顶结构方案是有效可行的,散热性能满足要求,简化结构,缩短换料大修时间,提升核电厂的可靠性和经济性。

Abstract:

[Objective] Scholars have extensively researched the development of the reactor head structure. Most studies focus on numerical analysis and partial experimental verification of temperature and flow fields in local areas surrounding specific reactor types. However, few studies examine the entire reactor pit. There is a lack of full-scale numerical simulations and experimental validation of natural convection flow fields and temperature fields covering the integrated reactor head structure, clusters of control rod drive mechanisms(CRDMs), reactor head cables, and reactor pit ambient conditions. This scarcity leaves a research gap in the comprehensive performance evaluation of the entire reactor pit. Based on the high-temperature-resistant control rod drive structure, this paper proposes an innovative design for the integrated reactor head structure. The proposed scheme eliminates the forced ventilation system for the reactor head. This approach enables modular installation and integral hoisting of the reactor head structure and components, which greatly simplifies refueling and overhaul of nuclear reactors. [Methods] In this research, the computational fluid dynamics(CFD) method is adopted. Following the coupling theory of heat conduction and convection with internal heat sources, the heat dissipation performance of three-phase media, including air, fluid, and metal inside the reactor head structure, is analyzed under two operating modes: natural convection and reactor cavity pool auxiliary ventilation. The flow field distribution of the reactor head structure and the heat dissipation effect of CRDM coils under diverse working conditions are thoroughly explored. Furthermore, a full-scale 1 : 1 test bench for the integrated reactor head structure is established to perform high-temperature ventilation tests to verify the accuracy and reliability of the numerical simulation results. The high-temperature ventilation test for the integrated reactor head structure realistically simulates the high-temperature ambient and heat dissipation conditions. The temperatures of CRDM coils, in the RGL(rod control and guide system)cables area, and in the RIC(reactor in-core instrumentation system) cables area of the reactor head structure comply with the design requirements. Compared with natural circulation, auxiliary ventilation markedly reduces the coil temperature and the air temperature around the reactor upper plenum. A comparison between test data and CFD simulation results shows that the overall variation trends of key reactor head structure components(including CRDM coils and air temperature distribution) are in good agreement, while certain deviations exist in the maximum temperature values. Under natural circulation conditions, the maximum temperature of high-temperature-resistant CRDM coils remains within the allowable range. The coil temperatures obtained from auxiliary ventilation tests match well with CFD predictions. However, the CFD-calculated coil temperatures under natural circulation are relatively low. Sensitivity analysis reveals that this discrepancy is associated with the setting of coil thermal resistance in the CFD model. The relatively low cable temperature in the RGL area under auxiliary ventilation is mainly attributed to the lower ambient temperature during the test. An obvious temperature difference exists between the test environment and the actual operating environment of a nuclear power plant. [Results] The results of CFD simulations and high-temperature ventilation tests on the integrated reactor head structure indicate that auxiliary ventilation through the reactor cavity pool delivers significantly superior heat dissipation performance compared with natural convection cooling. Coil temperature is reduced substantially, and the temperatures of all components in the reactor head structure are kept within permissible limits. The integrated reactor head structure adopts a truss structure, eliminating the forced ventilation system and seismic tie rods. [Conclusions] This design realizes modular installation and integral hoisting of the reactor head structure and simplifies the operation of upper plenum components during the opening and closing of the reactor head for refueling and overhaul. The integrated reactor head structure with auxiliary ventilation is proven effective and feasible. It meets all heat dissipation requirements, simplifies structural design, reduces refueling and overhaul times, and further enhances the operational reliability and economic efficiency of nuclear power plants.

参考文献

[1]魏乔苑,李跃忠,赵毛毛,等.一种用于核反应堆的新型无骨架耐高温线圈[J].材料导报, 2018, 32(增刊2):60–63.Wei Q Y, Li Y Z, Zhao M M, et al. A new type of high temperature resistant coil without frame used for nuclear reactor[J]. Materials Reports, 2018, 32(S2):60–63.(in Chinese)

[2]何培峰,许斌,罗英,等. ACP100集成式堆顶结构可压缩气体对流传热数值模拟[J].核技术, 2016, 39(10):100601.He P F, Xu B, Luo Y, et al. Numerical simulation on the convective heat transfer of compressive gas in ACP100 integrated head package[J]. Nuclear Techniques, 2016, 39(10):100601.(in Chinese)

[3]何培峰,许斌,罗英,等.基于HyperMesh的反应堆堆顶结构高质量计算流体力学网格生成[J].应用力学学报, 2017, 34(2):281–286.He P F, Xu B, Luo Y, et al. Generation of high quality computational fluid dynamics meshes for nuclear reactor head package by using HyperMesh[J]. Chinese Journal of Applied Mechanics, 2017, 34(2):281–286.(in Chinese)

[4]何培峰,刘昌文,罗英,等.基于华龙一号反应堆堆顶结构通风系统的数值模拟方法及试验验证[J].核动力工程, 2019,40(增刊1):16–19.He P F, Liu C W, Luo Y, et al. Numerical simulation method and test verification of ventilation system for HPR1000 integrated head structure[J]. Nuclear Power Engineering, 2019, 40(S1):16–19.(in Chinese)

[5]于浩,张明,冯少东,等. CAP1000一体化堆顶组件风冷系统流场分析[J].核技术, 2013, 36(4):122–125.Yu H, Zhang M, Feng S D, et al. CAP1000 integrated head package airflow system fluid field analysis[J]. Nuclear Techniques, 2013, 36(4):122–125.(in Chinese)

[6]莫少嘉,方健,段远刚,等.基于耐高温CRDM的堆顶结构散热性能研究[J].核科学与工程, 2024, 44(2):251–256.Mo S J, Fang J, Duan Y G, et al. Study on ventilation heat transfer performance of the reactor head package based on the high-temperature resistant CRDM[J]. Nuclear Science and Engineering, 2024, 44(2):251–256.(in Chinese)

[7]邹鹏,王建军,葛增芳,等.控制棒驱动机构自然循环冷却方式的可行性研究[J].核技术, 2014, 37(3):030604.Zou P, Wang J J, Ge Z F, et al. Feasibility research of CRDM natural circulation cooling[J]. Nuclear Techniques, 2014, 37(3):030604.(in Chinese)

[8]余志伟,何培峰,李燕,等. M310堆顶冷却结构流场和温度场数值仿真[J]. CAD/CAM与制造业信息化, 2014(7):43–48.Yu Z W, He P F, Li Y, et al. Numerical simulation of flow field and temperature field for m310 reactor top cooling structure[J].Digital Manufacturing Industry, 2014(7):43–48.(in Chinese)

[9]唐向东,李维.自然对流工况下堆顶三维温度场及流场数值模拟研究[J].核动力工程, 2023, 44(增刊2):44–49.Tang X D, Li W. Numerical simulation research on three-dimensional temperature field and flow field at the top of reactor under natural convection conditions[J]. Nuclear Power Engineering, 2023, 44(S2):44–49.(in Chinese)

[10]张志强,李维,付国忠,等.基于自然对流的堆顶局部热点分析及设计优化[J].科学技术创新, 2020(34):54–57.Zhang Z Q, Li W, Fu G Z, et al. Analysis and design optimization of local hot spots in the reactor top based on natural convection[J]. Scientific and Technological Innovation, 2020(34):54–57.(in Chinese)

[11]胡雪飞,罗英,王留兵,等.基于Taguchi方法的ACP100集成式堆顶冷却风管结构优化[J].中国核电, 2020, 13(6):788–794, 809.Hu X F, Luo Y, Wang L B, et al. Structure optimization for cooling vent of integrated head in ACP100 based on Taguchi method[J]. China Nuclear Power, 2020, 13(6):788–794, 809.(in Chinese)

[12]刘二林.压水堆核电厂反应堆堆顶高温原因分析及改进[J].机械设计与研究, 2021, 37(3):182–185.Liu E L. Cause analysis and solution of high temperature at PWR nuclear power plant’s reactor top(EMA)[J]. Machine Design and Research, 2021, 37(3):182–185.(in Chinese)

[13]Wagner W, PrußA. The IAPWS formulation 1995 for the thermodynamic properties of ordinary water substance for general and scientific use[J]. Journal of Physical and Chemical Reference Data, 2002, 31(2):387–535.

[14]International Atomic Energy Agency. Summary review on the application of computational fluid dynamics in nuclear power plant design:IAEA No. NR-T-1. 20[R]. Vienna:International Atomic Energy Agency, 2022.

[15]Wang M J, Wang Y J, Tian W X, et al. Recent progress of CFD applications in PWR thermal hydraulics study and future directions[J]. Annals of Nuclear Energy, 2021, 150:107836.

[16]Prasser H M, Kliem S. Coolant mixing experiments in the upper plenum of the ROCOM test facility[J]. Nuclear Engineering and Design, 2014, 276:30–42.

[17]Kütük B, GüzelbeyİH. Computational fluid dynamics analyses of a VVER-1200 nuclear reactor vessel for symmetric inlet,asymmetric inlet, and LOCA conditions[J]. International Journal of Pressure Vessels and Piping, 2020, 187:104165.

[18]Böttcher M, Bernard O, Mas A, et al. CFD analysis of coolant mixing in VVER-1000/V320 reactor pressure vessel[J]. Annals of Nuclear Energy, 2024, 197:110274.

[19]Zhao X H, Wang M J, Chen C, et al. Three-dimensional study on the hydraulic characteristics under the steam generator(SG)tube plugging operations for AP1000[J]. Progress in Nuclear Energy,2019, 112:63–74.

[20]Zhang X, Wang P F, Ruan X D, et al. Analysis of pressure pulsation induced by rotor-stator interaction in nuclear reactor coolant pump[J]. Shock and Vibration, 2017, 2017:7363627.

基本信息:

DOI:10.16791/j.cnki.sjg.2026.09.003

中图分类号:TM623

引用信息:

[1]方健,吴汉柱,李石磊,等.一体化堆顶结构研发及试验验证[J].实验技术与管理,2026,43(09):17-22.DOI:10.16791/j.cnki.sjg.2026.09.003.

发布时间:

2026-09-09

出版时间:

2026-09-09

网络发布时间:

2026-09-09

检 索 高级检索

引用

GB/T 7714-2015 格式引文
MLA格式引文
APA格式引文